The company's livestock animal test kits are distributed under the brand ListoX. A series of In-Field use rapid test kit are supplied to the farms and veterinarians.
Your Professional Farm Animal Supplier
J&G Biotech Ltd is a privately held company located in London, England. J&G Biotech Ltd and its corporates are engaged in the manufacturing and distribution of in vitro diagnostic products for companion animals, livestock, as well as rapid screening food safety test kits for veterinary drug residues, mycotoxins, and food-borne pathogens.
-
- Discription: Infectious Bovine Rhinotracheitis Antibody Rapid Test (IBR Ab). - Catalog No.:
Add to Inquiry -
- Discription: Ovine Anti-serotype A Foot and Mouth Diseases Antibody Rapid test(O.FMDV-A Ab). -
Add to Inquiry -
Bovine Escherichia coil K99 Ag
- Discription: Bovine Escherichia coil K99 Antigen Rapid Test (Escherichia coil K99 Ag). - Catalog
Add to Inquiry -
- Discription: Bovine Lumpy Skin Disease Virus Antibody Rapid Test (LSD Ab). - Catalog No.: JIB317.
Add to Inquiry -
- Discription: Ovine Brucella Antibody Rapid Test (O.Brucella Ab). - Catalog No.: JIO601. -
Add to Inquiry -
- Discription:Marek's Disease Virus Antigen Rapid Test (MDV Ag). - Catalog No.: JIA404. -
Add to Inquiry -
- Discription: Newcastle Virus Antibody Rapid Test (NDV Ab). - Catalog No.: JIA411. - Principle:
Add to Inquiry -
Bovine Coronavirus Antigen Rapid Test (BCV Ag)
The Bovine Coronavirus Antigen Rapid Test (BCV Ag) is a lateral flow immunochromatographic assay
Add to Inquiry -
The PPR Penside Test Kit for the detection of PPR virus. It is an immuno-chromatographic assay for
Add to Inquiry -
INTENDED USEThe FMDV-A Antibody Rapid Test is a lateral flow immunochromatographic assay for the
Add to Inquiry -
The FMDV-O Antibody Rapid Test is a lateral flow immunochromatographic assay for the qualitative
Add to Inquiry -
Newcastle Disease Virus Antigen Rapid Test
The Newcastle Disease Virus Antigen Rapid Test is a lateral flow immunochromatographic assay for
Add to Inquiry
Why Choose Us
Technical Team
Our technical team is a professional group in IVD field, consisting of several geniuses in genetic engineering, protein crystal structure, immunology, lateral flow technology, ELISA technology, IFA technology, nanotechnology and mold making.
OEM and ODM Services
We do provide OEM and ODM services. As a R&D manufacturer, we also offer the option to customize solutions to align with your specific requirements, especially if certain parameters are crucial for your project.
Quality Contral
J&G Biotech, pays much attention to product quality and design success rate. On the premise of guaranteeing high supply efficiency , all the products supplied by J&G Biotech are of high and steady quality. We are running ISO9001 and ISO13485 quality control systems to ensure the good quality of our products.
Certifications
Based on ISO9001&ISO13485, We will be unremittingly committed to improving product and service quality, focusing on rapid diagnostic (POCT) series product development and service upgrades, and striving to grow into an excellent rapid diagnostic (POCT) solution and technical service provider.
Farm Animal Specifications
|
Contents |
192 Tests/Kit |
|
FMDV 3ABC Antigen Coated Plates |
96-wells Plant×2 Pcs |
|
Sample Diluent |
60mL×1 Bottle |
|
Enzyme Marker (FMDV 3ABC) |
24mL×1 Bottle |
|
Positive Control Serum (FMDV 3ABC) |
1.5mL×1 Bottle |
|
Negative Control Serum (FMDV 3ABC) |
1.5mL×1 Bottle |
|
Substrate A solution |
12mL×1 Bottle |
|
Substrate B solution |
12mL×1 Bottle |
|
Stop solution |
12mL×1 Bottle |
|
20×Concentrated Washing Liquid |
40mL×1 Bottle |
|
Seal Film |
2 PCS |
|
Ziplock Bag |
2 PCS |
|
IFU |
1 PCS |
|
Specification |
192 Tests/Kit |
|
Storage Conditions and Term of Validity |
Store below 2~8°C. It is valid for 12 months. |
|
Sample Requirements |
Collect animal whole blood and prepare serum according to conventional methods. The serum is required to be clear and free of hemolysis. |
|
Amplification Instrument |
Microplate reader |
Features
Serotype Specificity:
FMDV has seven distinct serotypes (O, A, C, SAT1, SAT2, SAT3, Asia 1), and there is generally no effective cross-protection between them. Ovine FMDV-A antibodies are specific to the "A" serotype and will not protect the animal from other serotypes, such as "O" or "Asia 1".
Immune Response Indicator:
The presence of these antibodies indicates that a sheep has mounted an immune response to either an FMDV-A infection or an FMDV-A-specific vaccine.
Detection Method:
They are typically detected using serological methods, such as Enzyme-Linked Immunosorbent Assays (ELISA) or lateral flow immunochromatographic assays (rapid tests).
Monitoring Vaccination:
FMDV-A antibody tests are used to monitor antibody titers after vaccination to ensure the vaccine is effective and provides protective immunity.
Applications

Diagnostic Assays:
These antibodies are used in various serological tests, such as enzyme-linked immunosorbent assays (ELISAs), specifically sandwich ELISAs (DAS-ELISAs) and competitive ELISAs (cELISAs), to detect the presence of FMDV antigens or other FMDV-specific antibodies in animal samples.
Research and Development:
These antibodies serve as essential reagents in FMD research to understand the virus's immunobiology, characterize viral strains, and develop next-generation vaccines and diagnostic tools.


Disease Surveillance and Monitoring:
Ovine antibodies can be used in epidemiological studies and surveillance programs to track the spread of FMDV serotype A or O within animal populations and to monitor the effectiveness of vaccination campaigns.
Vaccine Efficacy Evaluation:
Specific monoclonal antibodies (mAbs) against FMDV type A have been developed and applied in diagnostic kits to determine the efficacy of FMDV type A vaccines in vaccinated cattle and sheep, often showing improved sensitivity over commercial alternatives.

Take the antigen coated plate(the plate can be open and used for several times according to sample quantity each time), add the diluted serum to reaction wells, 100ul/well; meanwhile, set 2 wells for positive control and 1 well for negative control, both positive control and negative control do not need dilute, take 100ul directly and add into its well, mix gently(do not overflow);
Cover it with Adhesive plate sealer, incubate at 37 ℃ for 30 minutes;
Open the adhesive plate sealer, discard the liquid of the well. Add diluted washing buffer to each well, 250ul/well,be static for 1min, then discard the liquid, repeat the above step for 4-6 times, at last flap to dry with the absorbent paper;
Adding Enzyme Conjugate,100ul/well, Cover it with Adhesive plate sealer, incubate at 37 ℃ for 30 minutes;
Open the adhesive plate sealer, discard the liquid of the well, washing 4-6 times as step 3, remember at last flap to dry with the absorbent paper;
Add substrate: Add Substrate 100ul/well, mix it evenly then cover it with Adhesive plate sealer, incubate at 37 ℃ in dark for 10 minutes;
Add stop solution 50ul/well to stop the reaction, measure the result in 10 minutes.